More info will be necessary to be more specific, though the troubleshooting page on this site has lots of info on this too. What would be the symptoms? Stay risk-free. ABAC Tech patented technology provides a smooth start-up and low motor loads, delivering powerful and uninterrupted compressed air. I think its time to return the compressor for a new one, return the regulator for a replacement (which they likely wont do as it was part of the compressor) or since these regulators sell for under $20 new, at a decent hardware or big box store that sells tools you might need to acquire a new one. Your post was moved to this page. Amazon and the Amazon logo are trademarks of Amazon.com, Inc or its affiliates. Compressor vibrating too much: tighten mounting bolts, and make sure the surface is level. Have tried getting pliers, needle nose vice grips, screw driver, even drilled hole through hub cap to solid axle trying to weaken the integrity of it. To continue visiting our website, please choose one of the following supported browsers. 5. : )[ Support Seeker ]Patrons and Other Support: http://wp.me/P6ivyU-1wTBuy Anything on Amazon and support Seeker when you use this link: https://amzn.to/2PeHRfq[ Shop ]Seeker Junk Store: http://www.svseeker.com/wp/sv-seeker-2/shop/Junk Store on Amazon http://www.amazon.com/shop/svseeker [ More ]Volunteer https://goo.gl/Lo1p6yAbout Us: http://www.svseeker.com/wp/sv-seeker-2/about-us/FaceBook Page: https://www.facebook.com/SailingVesselSeeker/FaceBook Group https://www.facebook.com/groups/svseeker/Blog: http://www.svseeker.com/wp/blog/ This is as far as I have gotten as I cant seem to find anybody in the UK the will service it. They are a 'plug & play' solution for air delivery. Always remember to check your owners manual to ensure that the correct parts are purchased. But, likely its power related, and that means checking the motor capacitors first. Full ABAC Catalogue. My compressor starts and runs for about a minute then it sounds like its seizing getting slower and then stops, if i then drain down the air its runs normal again for a minute then does the same again. Doesnt even try and turn!! Join 10.000 subscribers - subscribe to my newsletter for regular updates, tips and tricks. I drained the air, did the same test and realized it was bogging at closer to 40 psi. No idea what misfires means. Youll want to pull the compressor pump and motor cover and check out the direct drive shaft to ensure that its not broken or come unlinked some how. I plugged into my neighbors garage which apparently is 3 phase but still at least 25m from the house and the same issue. If none, empty the tank, pull the tank check valve and make sure its not compromised allowing air in but not out. Abac Go Cart OS20P manual 52 pages You are currently on the manuals page. How old? Nothing has worked. Pipe air intake to less humid air source. No change in behavior after changing each of these parts. What might the problem with my compressor be? AboutPressCopyrightContact. They are not the same for every compressor however, and since you dont tell us the make or model, no way can we check. This makes it pull in air throw the cooler. Where and why did you spray, and whats the make and model of the compressor please? The muffler keeps getting filled with gasoline,why would that be? 120 pages. I have new motor and air compressor. What are you looking for when it comes to maintain and repair your air compressor? What I did since then is. Why Am I Wasting Money On Compressed Air. I am adding an after cooler and was thinking about up sizing the line from the head from 3/8 compression tube to a 1/2 compression copper tube to the tank. I got it non working for a deal but have never gotten it to work. As the volume decreases the pressure increases. that has to be upgraded to 1/2. Bleed tank! Reset mechanism cuts out repeatedly; fuses of proper size blow. 9. So what causes the compressor to overheat? I have a Kobalt 99007 air compressor and the tires wont hold air. ABAC Genesis Air Compressors Here are the brilliant GENESIS ABAC compressors. My hausen cambell compressor has 2 tanks when air presure drop to a certain level the motor want kick back on. First step nothing should be coming out of the intake port. We have a highly qualified and experienced team of in-house engineers that provide quick, quality solutions at your doorstep. The other appears to be just a sound file. I did set it to 32 psi ( as recommended. However, that symptom is often associated with a leaking pump gasket or a pump head valve having failed. Your post was moved to this page as we couldnt determine what it is you were looking for with regards to your compressor. Please check that out and advise. Do the further checks, and please advise what you found. Got a problem with a specific brand of compressor? 1. Hi Joel. This website requires Javascript for some parts to function propertly. It was purchased in Canada, and I dont remember if it was branded as Craftsman or something else. Its just that the tubing needs a bend tool to keep it from crimping when bending to suit. In regards to more testing, this afternoon I tired various combinations of running the motor with air, without air, with the high pressure line connected/unconnected, as well as low pressure line connected/unconnected. The gun keeps leaking. Sounds like it could be a capacitor problem. Ive soaped every fitting, tightened those which were leaking. tested at 200PSI and 1/2NPT fittings no hardware included. In these troubleshooting 'basics' series I explain the most common problems and their solutions. I replaced the check valve with a new one. Choose one of the products to go directly to the manual for this product. I use this compressor for auto1976/2017car 1977truck & home a far amount of sand blasting small workbench cabinet, But as you know it a little bit small far this trying auto trans cooler help remove more water to try to get 3 min work done steps, rest let air build up so on. Air in tank, high pressure line connected, low pressure line disconnected-> motor will start, strain, and then stop. So continuity was checked through each wire & terminal, through the disconnect switch terminals & the pressure switch. Did that solve it? Tried both a new run and start capacitor and did not change. However, with the tank empty of air, power cord out of socket, look at the top of the piston / cylinder and look for cap screws or bolts. The lower support is mounted to the back of the handles bolts. Print. Have an Hitachi hot dog or twin tank small job site compressor. Compressor will not start / will not stop run issues, compressor has air coming out of the intake filter, compressor shuts off and all the air leaks out, air keeps leaking out of the pressure relief valve, air compressor cycles on and off all the time, compressor trips the breaker when restarting, compressor will not restart when air is used, new pressure switch and still the compressor wont stop, the lights dim when the air compressor starts, compressor trips breaker on pressure drop, how to find a replacement compressor capacitor, air keeps escaping from the oil fill plug. Check for worn crankshaft, keyway or pulley bore, resulting from running with loose pulleys. Thank you. Thanks for the photos, Dave. 2. In which case I dont understand what theyre for, and also how pressure from the cylinders is released when the motor stops? Hi, yeah I mean the pump and the model is a Clarke Air industrial XE29/270. I was assuming I would catch some water coming out of the tank before it reached the vertical aftercooler. So it should dump in the same time frame as it did. I have a 220v 500a60 Sanborn compressor that I am having some issues with. 7. will my air compressor take off lug nuts? Page 31 6. Air Compressor Will Not Build Pressure Troubleshooting, Compressor Wont Re-start When Air Is Used. One of the huge benefits of dealing with a professional company is their support. I did try to use new start capacitor and motor still was unable to start. If not, youll need to look closely to find where the air is escaping from. When performance issues arise with an air compressor, the problem can often be traced to heating issues. Will try to have it back online asap. Youve taken the check valve out of the equation by replacing it. And it will work with the M style industrial too.I all so use this V style coupler for the spare tank hookup when needed. That means that they are designed to run for a period of time, and then must be shut off and allowed to cool before they are run again, or they 1st go off on thermal cut out, and 2nd start to damage the motor. Try to determine if there are any mechanical impediments. Its in my garage which is 50m away from the house (power) so Im wondering if its as simple as my garage is a large extension lead! If that end of the air hose happens to be an air tool or valves or some such, thats where the crud will go. Sorry about your motor. I hope another visitor can comment. Parameters before startStrainer Inlet cleanOil level OKOil = BRAND new as FACTORY OIL, Parameters I check during I runningHP-with in the specsLP with in the specsOil level- OK. Not knowing the make or model of air compressor makes the possibility of anyone helping with the problem impossible. Knock occurs while compressor is loading. The tank valve isnt blocked because the air goes into the tank, and doesnt come out with the line to the valve fitting disconnected. Via Cristoforo Colombo 3 Brand new when I got it but never used it. ABAC compressors official 5 star distributor, of all ABAC and ALUP compressor and products, suppling mainland England. You are referring to an air compressor motor, yes? Put all new gaskets in the pump and I am still having this issue. It will run and build to about 40 psi then it acts like the pump is locking up then kicks back in then slows down again and will eventually kick the breaker on the electric motor. Filter by. In fact, they refer to the more than 300 distributors in more than 100 countries that represent Abac compressors.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[300,250],'fix_my_compressor_com-medrectangle-3','ezslot_3',815,'0','0'])};__ez_fad_position('div-gpt-ad-fix_my_compressor_com-medrectangle-3-0'); Abac offers a range of piston (reciprocating) air compressors, some with direct drive, and both single and two stage designs. At this point noticed the motor was straining and turned off the pressure control switch. I have a NorthStar (25653) 20gal compressor and want to use it with a pressure blaster. Check for bent crankshaft. As it builds pressure in the tanks it slows the motor from turning and will either stop the motor or make the belt slip.