118 This substance may not be transported under the provisions of Division 4.1 unless specifically authorized by the Associate Administrator (see UN0143 or UN0150 as appropriate). When portable tank instruction T75 is referenced in Column (7) of the 172.101 Table, the applicable refrigerated liquefied gases are authorized to be transported in portable tanks in accordance with the requirements of 178.277 of this subchapter. Additionally, self-propelled vehicles or equipment that contain a fuel cell engine must be described using the entries Engine, fuel cell, flammable gas powered or Engine, fuel cell, flammable liquid powered or Vehicle, fuel cell, flammable gas powered or Vehicle, fuel cell, flammable liquid powered, as appropriate. TP40 The portable tank must not be transported when connected with spray application equipment. N76 For materials of not more than 25 percent active ingredient by weight, packages consisting of inner metal packagings not greater than 250 mL (8 ounces) capacity each, packed in strong outer packagings together with sufficient absorbent material to completely absorb the liquid contents are authorized and need not conform to the requirements of part 178 of this subchapter. For vessel transport, the palletized loads, pallet boxes or unit load devices must be firmly packed and secured in closed cargo transport units; or. Dry batteries not specifically covered by another entry in the 172.101 Table are covered by this entry (i.e., Batteries, dry, sealed, n.o.s.) Formulations not meeting these criteria must be transported under the provisions applicable to the appropriate entry in the Organic Peroxide Table in 173.225 of this subchapter. N32 Aluminum materials of construction are not authorized for single packagings. B16 The lading must be completely covered with nitrogen, inert gas or other inert materials. Effective January 1, 2014, for transportation domestically by highway or rail, this entry may only be used if the results of Test Series 6(d) of Part I of the UN Manual of Tests and Criteria (IBR, see 171.7 of this subchapter) have demonstrated that any hazardous effects from accidental functioning are confined to within the package. Bulk packagings must have exterior heating coils fusion welded to the tank shell which have been properly stress relieved. The Code of Federal Regulations (CFR) is the official legal print publication containing the codification of the general and permanent rules published in the Federal Register by the departments and agencies of the Federal Government. 169 This entry applies to lighter refills (see 171.8 of this subchapter) that contain a Division 2.1 (flammable) gas but do not contain an ignition device. 238 Neutron radiation detectors: Neutron radiation detectors containing non-pressurized boron trifluoride gas in excess of 1 gram (0.035 ounces) and radiation detection systems containing such neutron radiation detectors as components may be transported by highway, rail, vessel, or cargo aircraft in accordance with the following: a. b. Packagings equivalent to DOT 406 cargo tanks are excepted from 178.345-7(d)(5), circumferential reinforcements; 178.345-10, pressure relief; 178.345-11, outlets; 178.345-14, marking, and 178.345-15, certification. B11 Tank car tanks must have a test pressure of at least 2,068.5 kPa (300 psig). This web site is designed for the current versions of Organization and Purpose It may be transported on cargo aircraft only with the prior approval of the Associate Administrator. Lead compounds which, when mixed in a ratio of 1:1,000 with 0.07 M (Molar concentration) hydrochloric acid and stirred for one hour at a temperature of 23 C 2 C, exhibit a solubility of 5% or less are not subject to the requirements of this subchapter unless they meet criteria as another hazard class or division. The packaging may not be loaded with a material outside of the packaging's design temperature range. B77 Other packaging are authorized when approved by the Associate Administrator. For non-pressurized lighters containing a Class 3 (flammable liquid) material, its design, description, and packaging must be approved by the Associate Administrator prior to being offered for transportation or transported in commerce. (5) N codes. b. b. B67 All valves and fittings must be protected by a securely attached cover made of metal not subject to deterioration by the lading, and all valve openings, except safety valve, must be fitted with screw plugs or caps to prevent leakage in the event of valve failure. Batteries and battery-powered device(s) containing batteries must be prepared and packaged for transport in a manner to prevent: (2) Short circuits, including but not limited to the following methods: (i) Packaging each battery or each battery-powered device when practicable, in fully enclosed inner packagings made of non-conductive material; (ii) Separating or packaging batteries in a manner to prevent contact with other batteries, devices or conductive materials (e.g., metal) in the packagings; or, (iii) Ensuring exposed terminals or connectors are protected with non-conductive caps, non-conductive tape, or by other appropriate means; and. B68 Sodium must be in a molten condition when loaded and allowed to solidify before shipment. 43 The membrane filters, including paper separators and coating or backing materials, that are present in transport, must not be able to propagate a detonation as tested by one of the tests described in the UN Manual of Tests and Criteria, Part I, Test series 1(a) (IBR, see 171.7 of this subchapter). TP36 For material assigned this portable tank special provision, portable tanks used to transport such material may be equipped with fusible elements in the vapor space of the portable tank. When such batteries are transported in accordance with 173.185(c), the total lithium content of all lithium metal cells contained in the battery must not exceed 1.5 g and the total capacity of all lithium ion cells contained in the battery must not exceed 10 Wh. A8 For combination packagings, if glass inner packagings (including ampoules) are used, they must be packed with cushioning material in tightly closed metal receptacles before packing in outer packagings. The toy plastic or paper caps must be in the form of sheets, strips, rolls, or individual caps; b. 352 Ammonium chlorite, ammonium chlorite aqueous solutions, and mixtures of a chlorite with an ammonium salt are forbidden for transport. The Packing Group assigned will be II or III, according to the classification criteria for either Class 3 or Division 4.1, as appropriate, applied to the base material. Interior heating coils are not authorized. If you would like to comment on the current content, please use the 'Content Feedback' button below for instructions on contacting the issuing agency. B5 Only ammonium nitrate solutions with 35 percent or less water that will remain completely in solution under all conditions of transport at a maximum lading temperature of 116 C (240 F) are authorized for transport in the following bulk packagings: MC 307, MC 312, DOT 407 and DOT 412 cargo tanks with at least 172 kPa (25 psig) design pressure. user convenience only and is not intended to alter agency intent The pressure relief device must be preceded by a frangible disk in accordance with the requirements in 178.275(g)(3) of this subchapter to prevent crystallization of the product in the pressure relief device. Capacitors with an energy storage capacity of 0.3 Wh or less are not subject to the requirements of this subchapter. (v) UN and IM portable tank codes/special provisions. For single packagings, each packaging must correspond to a design type that has passed a leakproofness test at the Packing Group II level. The total mass of lithium batteries contained in any package must not exceed the quantity limits in columns (9A) and (9B) for passenger aircraft or cargo aircraft, as applicable; b. Table I - Maximum Ambient Temperature - Gasoline. B49 Tanks equipped with interior heater coils are not authorized. (TOY CAPS) - HANDLE CAREFULLY OR TOY CAPS - HANDLE CAREFULLY; and. The unintended errors are summarized below. (2) A codes. In this case, some parts of the vehicle may be detached from its frame to fit into the packaging. 15, 1976, unless otherwise noted. These mixtures may be classified in Division 4.1 when tested in accordance with test series 6(c) of the UN Manual of Tests and Criteria (IBR, see 171.7 of this subchapter) and approved by the Associate Administrator. The material may only be loaded with Class 3, Class 8, and Division 4.1 materials in Packing Group II or III. TP2 a. be marked with the hydrostatic pressure test marking specified in 173.24a(b)(4). TABLE 2 lists . W7 Vessel stowage category for uranyl nitrate hexahydrate solution is D as defined in 172.101(k)(4). Packages containing mixtures with not less than 90% by mass, of phlegmatizer need not bear a POISON subsidiary risk label. N11 This material is excepted for the specification packaging requirements of this subchapter if the material is packaged in strong, tight non-bulk packaging meeting the requirements of subparts A and B of part 173 of this subchapter. The suitability for transport in tanks must be demonstrated using test 8(d) in Test Series 8 (see UN Manual of Tests and Criteria, Part 1, Sub-section 18.7) (IBR, see 171.7 of this subchapter) or an alternative means approved by the Associate Administrator. Note that batteries utilizing different chemistries (i.e., those battery chemistries specifically covered by another entry in the 172.101 Table) as well as dry batteries with a marked rating greater than 9-volt may not be combined with used or spent batteries in the same package. Solid substances transported or offered for transport above their melting point are authorized for transportation in portable tanks conforming to the provisions of portable tank instruction T4 for solid substances of packing group III or T7 for solid substances of packing group II, unless a tank with more stringent requirements for minimum shell thickness, maximum allowable working pressure, pressure-relief devices or bottom outlets are assigned in which case the more stringent tank instruction and special provisions shall apply. 110 Fire extinguishers transported under UN1044 and oxygen cylinders transported for emergency use under UN1072 may include installed actuating cartridges (cartridges, power device of Division 1.4C or 1.4S), without changing the classification of Division 2.2, provided the aggregate quantity of deflagrating (propellant) explosives does not exceed 3.2 grams per cylinder. 421 This entry will no longer be effective on January 2, 2023, unless we terminate it earlier or extend it beyond that date by notice of a final rule in the Federal Register. W100 Non-bulk flexible, fibreboard or wooden packagings must be sift-proof and water-resistant or must be fitted with a sift-proof and water-resistant liner. per pound of hydrogen peroxide solution. B26 Tanks must be insulated. Packagings must be sift-proof, prevent liquid water from reaching the hazardous material, and be provided with sufficient venting to preclude dangerous accumulation of flammable, corrosive, or toxic gaseous emissions such as methane, hydrogen, and ammonia. 2 Except when authorized under Special Provision 41. Each portable tank constructed of metal must be fitted with a pressure-relief device consisting of a reclosing spring loaded type, a frangible disc or a fusible element. Thickness of stainless steel for tank shell and heads must be the greater of 7.62 mm (0.300 inch) or the thickness required for a portable tank with a design pressure at least equal to 1.5 times the vapor pressure of the hazardous material at 46 C (115 F). N73 Packagings consisting of outer wooden or fiberboard boxes with inner glass, metal or other strong containers; metal or fiber drums; kegs or barrels; or strong metal cans are authorized and need not conform to the requirements of part 178 of this subchapter. 107 The classification of the substance is expected to vary especially with the particle size and packaging but the border lines have not been experimentally determined; appropriate classifications should be verified following the test procedures in 173.57 and 173.58 of this subchapter. However this examination is required when the conditions of 180.605(f) are met. Packaging must be UN standard metal drums attached with heavy duty steel strapping to a pallet; and. c. Completed neutron radiation detection systems containing detectors meeting the conditions of paragraph a of this special provision must be transported as follows: (1) The detectors must be contained in a strong sealed outer casing; (2) The casing must contain include sufficient absorbent or adsorbent material to absorb or adsorb the entire gas contents; (3) The completed system must be packed in strong outer packagings capable of withstanding a 1.8 meter (5.9 feet) drop test without leakage unless a system's outer casing affords equivalent protection.
Samoan Girl Names,
Glasgow Airport Covid,
Where Can I Cash A Charles Schwab Check,
Lincoln High School Teachers,
Articles C